Fused Quartz Tubing Category

TUBING TOLERANCES



TUBING TOLERANCES

DIAMETER
RANGE
(mm)

DIAMETER
REFERENCE
 

DIAMETER
NOMINAL
%

OUT OF ROUND
% OF O.D.
MAXIMUM

WALL
THICKNESS
 

SIDING
MAXIMUM
% WALL

BOW
1200
(mm)

LENGTH
(mm)
 

UP TO 5.9 O.D. ± 2.5% 2% ± 10% 10% 2 ± 3.2
6–35 O.D. ± 2% 1.5% ± 10% 10% 2 ± 3.2
35.1–79.9 O.D. ± 2% 1.5% ± 10% 10% 2 ± 6.4
80–150 O.D. ± 2% 1.2% ± 10% 20% 2 ± 6.4
151–189 O.D. ± 2% 1.2% ± 20% 20% 2 ± 9.5
190 UP O.D. ± 2% 1.2% ± 25% 20% 2 ± 12.7
To view an enlarged version of this chart, click HERE